TNNI3 Paired antibodies, capture and conjugating are used for lateral flow immunoassay. The sensitivity to detect Cardiac Troponin-I in the blood as declared by the FDA is 5ng/ml. The concentration needed when using the paired antibodies could reach 3-4ng/ml. We highly recommend using our cat# pro-2266 in the rapid test. The minimal detection quantity of recombinant Cardiac Troponin-I is 0.25 to 0.5ug/ml.Please note that when ordering for example: 100µg antibody we ship 50µg from each of the antibodies (100µg in total).
Synonyms: Troponin I cardiac muscle, Cardiac troponin I, TNNI3, TNNC1, CMH7, RCM1, cTnI, CMD2A, MGC116817.
Formulation: * Cardiac Troponin-I capture antibody in 1x PBS & NaN3.* Cardiac Troponin-I conjugating antibody in 1x PBS & NaN3.
Physical Appearance: 2 vials of sterile filtered clear colorless solution.
Purity: Greater than 95%.
Transportation method: Shipped with Ice Packs
Stability: Cardiac Troponin-I although stable at 4°C for 1 week, should be stored below -18°C.For long term storage it is recommended to add a carrier protein (0.1% HSA or BSA).Please prevent freeze-thaw cycles.
Purification Method: Purified monoclonal IgG by protein A chromatography.
Type: Mouse Anti Human Monoclonal.
Applications: Lateral flow immunoassay.
Safety data sheet: Inquire at info@3hbiomedical.com